Regulator
- * Rolling diaphragm.
- * The set pressure is kept stable regardless of upstream variations.
- * High flow rate with low load losses.
- * Downstream overpressures quickly eliminated.
- * Lockable safety knob.
- * Can be wall mounted using the relative holes or on bracket.
- * Pressure ranges:
- 0¸4 Bar, 0¸8 Bar (standard),0¸12,5 Bar
- 0¸0,4 MPa, 0¸0,8 MPa (standard), 0¸1,25 MPa
- * Maximum inlet pressure: 12,5 Bar (1,25 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=6,3 Bar - Dp=1 Bar): 1500 Nl/min.
- * Weight: 0,325 Kg.
|
|
|
|
|
 |
|
|
|
| Back to the top of page |
|
|
|
|
 |
Filter
- * High level of condensate separation.
- * Low pressure drop.
- * Can be wall mounted by using the relative holes.
- * Quick bowl connection by means of the safety ring mechanism.
- * Filtering degree: 5 micron and 20 micron (standard).
- * Manual and semiautomatic condensate drainage in the integrated (S) or float
- type automatic version (A).
- * Bowl in toughened polyamide with outer bowl guard.
- * Collected quantity of condensate: 42 cc.
- * Maximum operating pressure 12,5 Bar (1,25 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=10 Bar - Dp=1 Bar): 2500 Nl/min.
- * Weight: 0,225 Kg.
Coalescent Oil Vapour Removal Filter
- Essential in circuits where oil is not permitted.
- * Coalescent cartridge made in microfiber, allows an high filtration efficiency of
- 99,99% on 0,1 micron particles.
- * Long-lasting filtering element.
- * Can be wall mounted using the relative holes.
- * Manual and semiautomatic condensate drainage in the integrated (SS) or float
- type automatic version (SA).
- * Bowl in toughened polyamide with outer bowl guard.
- * It is advisable to install a filter with 5 micron element, to consent long-lasting
- of coalescent cartridge.
- * Maximum operating pressure 12,5 Bar (1,25 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=6,3 Bar - Dp=1 Bar): 270 Nl/min.
- * Weight: 0,221 Kg.
|
|
| Back to the top of page |
|
|
|
|
|
|
|
 |
Lubricator
- Proportional oil mist type.
- * Constantly steady delivery.
- * Suction ensured even at low flow rates.
- * Sensitive lubricant flow adjustment.
- * 360°C drip display.
- * Oil fill plug.
- * Can be wall mounted using the relative holes.
- * Bowl in toughened polyamide with outer bowl guard.
- * Bowl capacity: 68 cc.
- * Recommended oil viscosity ISO VG32.
- * Maximum operating pressure: 12,5 Bar (1,25 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=10 Bar - Dp=1 Bar): 2000 Nl/min.
- * Weight: 0,230 Kg.
Lubricator with level indicator
- * This version is equipped with a float level indicator, that allows to receive an
- electric signal able to control acoustic and luminous alarm, when into the bowl
- the oil reaches the minimum level.
- * Bowl capacity: 61 cc.
- * Maximum voltage: 100V AC/DC.
- * Contact: 0,75A 10W.
- * Protection degree: IP 65.
- * Other functional features, like standard model.
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=6,3 Bar - Dp=1 Bar): 1700 Nl/min.
- * Maximum working pressure: 7 Bar (0,7 MPa).
- * Weight: 0,260 Kg.
|
|
 |
|
|
 |
|
|
| Back to the top of page |
|
|
|
|
|
|
 |
Automatic Filling Lubricator
- * Essential when the oil must be quickly and safely loaded without interrupting
- the normal operation of the system.
- * Filling is achieved by keeping the button at the base of the lubricator casing
- depressed. This provokes a vacuum inside the cup enabling the oil to be intaken.
- * The flow will only interrupt when the button is released.
- * The oil level must be visually inspected.
- * Minimum attivation pressure: 3 Bar (0,3 MPa).
- * Other functional features as standard model.
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=10 Bar - Dp=1 Bar): 2000 Nl/min.
- * Weight: 0,270 Kg.
|
|
| Back to the top of page |
|
|
|
|
|
|
|
Filter Regulator
- * Rolling diaphragm.
- * The set pressure is kept stable regardless of upstream variations.
- * Large capacity with low load losses.
- * Downstream overpressures quickly eliminated.
- * Lockable safety knob.
- * High condensate separation level.
- * Quick bowl connection by means of safety ring mechanism.
- * Can be wall mounted using the relative holes or on bracket.
- * Pressure ranges:
- 0¸4 Bar, 0¸8 Bar (standard), 0¸12,5 Bar
- 0¸0,4 MPa, 0¸0,8 MPa (standard), 0¸1,25 MPa
- * Filtering degree: 5 micron and 20 micron (standard).
- * Manual and semiautomatic condensate drainage in the integrated (SS) or float
- type automatic version (SA).
- * Bowl in toughened polyamide with outer bowl guard.
- * Collected quantity of condensate: 42 cc.
- * Maximum operating pressure: 12,5 Bar (1,25 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=6,3 Bar - Dp=1 Bar): 1500 Nl/min.
- * Weight: 0,410 Kg
|
|
 |
|
|
|
 |
|
|
| Back to the top of page |
|
|
|
|
|
 |
3 Way on-off valve with lock
- * Used to shut off the air supply while relieving the downstream circuit.
- * The block device is particularly useful during maintenance operations. It prevents
- the system from being accidentally or wrongly pressurized.
- * It can be wall mounted using the relative holes.
- * Discharge connection: G1/4".
- * Maximum inlet pressure: 12,5 Bar (1,25 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * The device is equipped with 1 lock.
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=10 Bar - Dp=1 Bar): 2580 Nl/min.
- * Weight: 0,270 Kg.
|
|
|
|
|
 |
|
|
| Back to the top of page |
|
|
|
|
 |
Shut-off Valve
- * Device used to shut off the air supply while relieving the downstream circuit by
- a remote electric control.
- * Available with MICROSOL type or in compliance with CNOMO standards remote
- electric control (to be ordered separately).
- * Available with remote pneumatic control.
- * It can be wall mounted using the relative holes.
- * Discharge connection: G1/4".
- * Minimum pressure admitted: 3 Bar (0,3 MPa).
- * Maximum working pressure: 10 Bar (1 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=10 Bar - Dp=1 Bar): 2580 Nl/min.
- * Weight: 0,280 Kg.
|
|
|
|
 |
|
|
| Back to the top of page |
|
|
|
|
|
 |
Slow start Valve
- Gradually pressurizes the system until reaching the set operating pressure value.
- * Before delivering the maximum available pressure, the air is allowed to slowly
- flow around the downstream circuit until about 60% of the pressure is reached
- upstream.
- * Use the built-in flow governor to establish the pressurizing time.
- * It can be wall mounted using the relative holes.
- * Minimum pressure admitted: 3 Bar (0,3 MPa).
- * Maximum working pressure: 10 Bar (1 MPa).
- * Temperature range: 5¸50°C (41¸122°F).
- * Max. torque inserts G3/8” IN-OUT: 60 N·m.
- * Max. torque inserts G1/2” IN-OUT: 80 N·m.
- * Reference flow rate (P=10 Bar - Dp=1 Bar): 2580 Nl/min.
- * Weight: 0,270 Kg.
|
|
|
|
 |
|
|